Features:
Model: | HP/HP-T | AU10212 | AU32224 | AU50248 | AU72248 | ||
---|---|---|---|---|---|---|---|
Rated Power | 1000W | 3200W | 5000W | 7200W | |||
Peak Power (20ms) | 3000VA | 9000VA | 15KVA | 21.6KVA | |||
Battery Voltage | 12VDC | 24VDC | 48VDC | 48VDC | |||
Product Size (L*W*Hmm) | 411.5x283x88 | 476x350x118 | 538x388x118 | ||||
Package Size (L*W*Hmm) | 459x345x147 | 502x402x165 | 561x454x167 | ||||
N.W (Kg) | 7 | 11.5 | 11.8 | 16 | |||
G.W (Kg) | 8 | 12.5 | 12.8 | 17.5 | |||
Installation Method | Wai I-Mounted | ||||||
Inside MPPT Solar controller (Optional) | Charging Mode | MPPT | |||||
Rated PV input voltage | 360VDC | ||||||
MPPT tracking voltage range | 120V-450V | ||||||
Max PV Input VoltagefVoc) (At the lowest temperature) | 500V | ||||||
PV Array Maximum Power | 1500W | 4000W | 4000W*2 | ||||
MPPT tracking channels (input channels) | 1 | 1 | 2 | ||||
Inside PWM Solar | Charging Mode | PWM | |||||
Charging current | 30A | 60A/120A | |||||
PV Input Voltage Range | 15-44V | 30-44V | 60-88V | ||||
controller (Optional) | Max Pv input voitage(vocj (At the lowest temperature) | SOV | 100V | ||||
PV Array Maximum Power | 420W | 1680W/3360W | 3360W/6720W | ||||
PV input channels | 1 | 1or2 | |||||
Input | DC Input Voltage Range | 10.5VDC-15VDC | 21VDC-30VDC | 42VDC-60VDC | |||
Rated AC input voltage | 220VAC /230VAC /240VAC | ||||||
AC Input Voltage Range | 170VAC-280VAC (UPS mode) /120VAC-280VAC (INV mode) | ||||||
AC Input Frequency Range | 45Hz~55Hz (50Hz), 55Hz~65Hz (60Hz) | ||||||
Output | Peak value of output efficiency (Battery/PV Mode) | 94%(peak value) | |||||
Output Voltage(Battery/PV Mode) | 220VAC±2% /230VAC±2% /240VAC±2% | ||||||
Output Frequency(Battery/PV Mode) | 50Hz±0.5 or60Hz±0.5 | ||||||
Output Wave( Battery/PV Mode) | Pure Sine Wave | ||||||
Efficiency(AC Mode) | 2.99 | ||||||
Output Voltage(AC Mode) | Follow input | ||||||
Output Frequency(AC Mode) | Follow input | ||||||
Output waveform distortion (Battery/PV Mode) | £3%(Linear load) | ||||||
No load loss(Battery Mode) | 《1% rated power | ||||||
No load loss(AC Mode) | <1 % rated power(charger does not work in AC mode) | ||||||
Battery | Battery Type | VRLA Battery | Charge Voltage :13.8V; Float Voltage” 3.7V(Single battery voltage) | ||||
Customize battery | Charging and discharging parameters of d iff ere nt types of batteries can be customized according to user requirements (charging and discharging parameters of different types of batteries can be set through the operation panel) | ||||||
Maximum charging current (Mains or PV or mains + PV) (Built-in MPPT controller model) | 40A | 60A | 50A | 60A | |||
Maximum charging current (Built-in PWM controller model) | Mains40A+ PWM controller charging current | Mains60A+ PWM controller charging current | Mains50A+ PWM controller charging current | Mains60A+ PWM controller charging current | |||
Charging method | Three-stage (constant current, constant voltage, floating charge) | ||||||
Protection | Battery low voltage alarm | Battery undervoltage protection value+0.5V(Single battery voltage) | |||||
Battery low voltage protection | Factory default: 10.5V(Single battery voltage) | ||||||
Battery over voltage alarm | Constantchargevoltage+0.8V(Single battery voltage) | ||||||
Battery over voltage protection | Factory default: 17V(Single battery voltage) | ||||||
Battery over voltage recovery voltage | Battery overvoltage protection value-1 V(Single battery voltage) | ||||||
Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||
Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | ||||||
Temperature protection | >90°C(Shut down output) | ||||||
Working Mode | Mains priority/Solar priority/Battery priority(Can be set) | ||||||
Transfer Time | ^4ms | ||||||
Display | LCD+LED | ||||||
Thermal method | Cooling fan in intelligent control | ||||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||||
Environment | Operating temperature | -10X~40°C | |||||
Storage temperature | -15°£~60< | ||||||
Noise | £55dB | ||||||
Elevation | 2000m(More than derating) | ||||||
Humidity | 0%~95% (No condensation) | ||||||
Warranty 1 year |
Note: 1. The working mode of the built-in MPPT controller model supports PV priority/battery priority/mains priority, and the working mode of the built-in PWM controller
model only supports battery priority/mains priority;
2. All specifications are subject to charge without prior notice.
AUSTA is a high-tech enterprise under OSDA group who is the 14GW solar module manufacture located in Ningbo, China since 2007. Austa is always committed to the research and development the production of solar inverter and continue to pursue technological innovation.